The Fluke 287 is a True-rms logging multimeter with TrendCapture graphing, a 50,000 count 1/4 VGA backlit display and 0.025 % basic dc accuracy. It measures up to 1000 V, 10 A, 500 MΩ, 100 mF and temperature, and stores up to 15,000 events.
The Fluke 287 quickly documents design performance and graphically displays what happened. Its unique logging and graphing capabilities mean you no longer need to download logged readings to a PC to detect a trend.
With a large 50,000 count, 1/4 VGA white backlit display, the meter shows multiple sets of measurement information at the same time, while on-board help screens and a multi-lingual interface make it easy to use on the bench or in the field.
It measures dc and ac voltage up to 1000 V, current up to 10 A (20 A for 30 seconds), resistance up to 500 MΩ, capacitance up to 100 mF, frequency up to 999.99 kHz and temperature from -200.0 °C to 1350.0 °C, with True-rms ac bandwidth specified to 100 kHz.
| Manufacturer | Fluke |
|---|---|
| Model | 287 |
| DC volts / AC volts range | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
| Voltage basic accuracy | 0.025 % (DC), 0.4 % (AC true-rms) |
| DC / AC current range | 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
| Current basic accuracy | 0.15 % (DC), 0.7 % (AC true-rms) |
| Temperature (excluding probe) | -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F), 1.0 % |
| Resistance | 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ — 0.05 % |
| Capacitance | 1.000 nF to 100 mF — 1.0 % |
| Frequency | 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz — 0.005 % |
| True-rms ac bandwidth | 100 kHz |
| DC mV resolution | 1 µV |
| Conductance | 50.00 nS |
| Peak | 250 µS |
| Duty cycle | 0.01 % to 99.99 % |
| Pulse width | 0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms |
| Logging memory | up to 10,000 readings |
| Display | 50,000 count, 1/4 VGA with white backlight |
| Maximum voltage (terminal to earth) | 1000 V |
| Battery type | 6 AA alkaline batteries, IEC LR6 |
| Battery life | 100 hours minimum, 200 hours in logging mode |
| Operating temperature | -20 °C to 55 °C |
| Storage temperature | -40 °C to 60 °C |
| Relative humidity | 0 to 90 % (0 to 37 °C), 0 to 65 % (37 °C to 45 °C), 0 to 45 % (45 °C to 55 °C) |
| Electromagnetic compatibility | IEC 61326-1: Portable |
| Safety | IEC 61010-1 Pollution degree 2; IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V |
| Size (HxWxL) | 22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38 in) |
| Weight | 870.9 g (28 oz) |